Three Grades, each with defined accuracy

For use with Vector Network Analysers – 1.14 GHz to 500 GHz.

Three grades of calibration kits and components are available that enable VNA users to select the one most suitable for the analyser type and measurement requirement. Various manufacturing techniques are employed and selected according to waveguide size and required accuracy.

Critical components in each grade of kit have defined accuracies – a feature unique to Flann Waveguide Calibration Kits. Flann calibration kits contain all the components necessary to fully calibrate VNAs configured for waveguide measurements. A typical kit would include waveguide to coax adaptors, fixed terminations, a sliding termination, offsets, flush shorts and a waveguide section. Kits are supplied in a fitted hardwood case complete with connecting hardware, data disc and handbook.

 

Model Selection Table

Kit GradeKit Type
OOLTRL / LRL
Metrology Bronze708 series703 series
Metrology Silver730 series720 series
Metrology Gold750 series740 series

 

Each kit type contains the following components

ComponentsContents
OOLTRL / LRL
Waveguide to Coax Adaptors
1.14 GHz to 22 GHz
(WG6, WR650, R14) to (WG19, WR51, R180)
2 off2 off
17.6 GHz to 110 GHz
(WG20, WR42, R220) to (WG27, WR10, R900)
2 off optional extra2 off optional extra
Fixed Termination2 off2 off
Flush Short2 off2 off
1/8 λ Offset1 offoptional extra
1/4 λ Offsetoptional extra1 off
3/8 λ Offset1 offoptional extra
Waveguide Section1 off1 off
Sliding Termination1 offoptional extra
Data Diskincludedincluded
Torque Driverincludedincluded
Flange Bolts etc1 set included1 set included
Precision Flange dowels1 set included1 set included
Hardwood Caseincludedincluded
Handbookincludedincluded

Note 1 – Flanges

Flann Calibration Kit components are fitted with “Precision Flanges” that are fully compatible with standard flanges whilst providing enhanced accuracy and repeatability.
Kits are also available fitted with alternative flange styles or special flanges to customer specification. Details on request.

Note 2 – Waveguide to Coax Adaptors

The Waveguide to Coax Adaptors supplied with Flann Calibration Kits are of sufficientlength to ensure the decay of unwanted evanescent modes.

Note 3 – Offsets

The length of each Flann offset section is designed to provide a phase balanced responseover the recommended frequency range. Fractional wavelengths are specified withrespect to a wavelength λg° where:-


λglf is the waveguide wavelength at the lowest frequency of the operating range and λghf is the waveguide wavelength at the highest frequency of the operating range.

 

Flann Calibration Kits have been developed in close cooperation with manufacturers and users of network analysers. Kits are available in each of the three grades, suitable for analyser configurations requiring OOL, TRL and LRL calibration kit styles. The selection of a calibration kit and its contents is largely dictated by the combination of analyser model, test set model and type of calibration routine to be implemented, i.e. full 12 term, single path 2 port, reflection only or TRL/LRL.

OOL – Offset/Offset/Load
TRL – Thru/Reflect/Line
LRL – Line/Reflect/Line

The waveguide Calibration Kits contain the components necessary to fully calibrate Vector Network Analysers. Flann Calibration Kit components are available individually or to supplement standard kits. Specialised Calibration Kits or components for use with alternative measurement systems, such as six port reflectometers, are also available. Full details are available on request.

Note: The components included in Flann Offset/Offset/Load type calibration kits can also be used with the Anritsu/Wiltron 360 to achieve an LRL calibration.

The specifications and capabilities of network analysers are subject to constant evolution and development. Please consult us for Calibration Kit applications assistance if required.

Note 1 – Flanges

Flann Calibration Kit components are fitted with “Precision Flanges” that are fully compatible with standard flanges whilst providing enhanced accuracy and repeatability. Kits are also available fitted with alternative flange styles or special flanges to customer specification. Details on request.

Note 2 – Waveguide to Coax Adaptors

The Waveguide to Coax Adaptors supplied with Flann Calibration Kits are of sufficient length to ensure the decay of unwanted evanescent modes.

Note 3 – Corner Radius

Calibration Kits with specified corner radius are available – please contact our Sales Department for more details

Please Note: Calibration Kits in WG 20 and higher frequency sets (17.6 GHz upwards) do not include waveguide to coax adaptors.
Please state at time of ordering if adaptors will be required.
Double Ridge Waveguide Calibration Kits are also available

    Contact Form

    Your Name (required)

    Your Email (required)

    Company

    Country

    Your Message