Features

  • Systems Grade
  • Ideal For Power / Frequency
    Sampling & Monitoring

ModelFrequency Range (GHz)WaveguideMinimum Directivity (dB)Coupling (10 dB &20 dB)Primary Arm VSWRSecondary Arm VSWR
WGRWRSensitivity
(± dB)
Nominal
Accuracy (dB)
101302.60 - 3.951032284350.55%1.031.1
11A1303.22 - 4.9011A40229350.55%1.031.1
121303.94 - 5.991248187350.55%1.031.1
131304.64 - 7.051358159350.55%1.031.1
141305.38 - 8.181470137350.55%1.031.1
151306.58 - 10.01584112350.55%1.031.1
161308.20 - 12.51610090350.55%1.031.1
171309.84 - 15.01712075350.55%1.031.1
1813011.9 - 18.01814062350.55%1.031.1
1913014.5 - 22.01918051330.55%1.031.1
2013017.6 - 26.72022042330.757%1.031.2
2113021.7 - 33.02126034330.757%1.031.2
2213026.4 - 40.12232028330.757%1.031.2
ModelDimensions (mm)Weight (kg)
ABC
10 dB20 dB10 dB20 dB
10130121510298513010.68.0
11A130965817701005.74.6
1213085373360904.33.0
1313078567655753.52.6
1413070661550602.62.2
1513053446035501.51.3
1613047641735451.00.8
1713038733835400.80.6
1813034029830350.50.4
1913030026230350.40.3
2013022820125250.180.16
2113021519425250.180.16
2213018016224290.160.14

    Contact Form

    Your Name (required)

    Your Email (required)

    Company

    Country

    Your Message